MECHANICAL AND ELECTRICAL SPECIFICATIONS | |
---|---|
Display | 6 ½ digits LCD h = 13 mm and negative sign |
Programmable resolution | 1.0 — 0.1 — 0.05 — 0.01 mm 0.01 — 0.001 — 1/16 — 1/32 — 1/64 inch 1° — 0.1° — 0.01° — 0.001° angular |
Repeatability | ± 1/2 digit |
Power supply | Batteries x2 LR6 AA External (1,5…5 V) |
Operating temperature range | 0°C to +50°C |
Storage temperature range | -20°C to +70°C |
Humidity | 95% (not condensed) |
Readout weight | 100 g |
Readout Vibration (EN 60068-2-6) | 25 m/s² (55Hz…2000Hz) |
Readout Protection class (EN 60529) | IP 43 |
SENSOR SPECIFICATIONS | |
---|---|
Maximum speed | 4 m/s |
Sensor — magnetic band gap | 0,3…2 mm |
Accuracy | ± 20 μm |
Magnetic band to be used with – pole pitch | CSM (2+2mm) |
Vibration (EN 60068-2-6) | 300 m/s² (55Hz…2000Hz) |
Shock (EN 60068-2-27) | 1000 m/s² (11 ms) |
Protection class (EN 60529) | IP 67 |
BAND SPECIFICATIONS | |
---|---|
Pole pitch | 2+2 mm |
Accuracy at 20°C | ±30 μm/m |
Width band | 10 mm |
Thickness band | 1,3 mm |
Maximum length | 50 m |
Thermal expansion | 10,5 x 10¯⁶ °C¯¹ T ref = 20°C ± 0,1°C |
Bending radius | ≥ 130 mm |
Operating temperature range | 0°C to 70°C |
Storage temperature range | -20°C to 80°C |
IMPORTANT: In order not to compromise the accuracy of the system, the magnetic band must be longer than the machine run of at least 4 cm from each side.