VI96 DISPLAY

IMPULSE COUNTER, RATEMETER AND PERIODMETER

  • Reading at 6 digits with 14 mm digit height
  • Standard size of 96 x 48 mm
  • Admits all type of impulse signals and encoders
  • Provides excitation voltage fot the sensor
  • Universal high and low AC and DC power options
  • Optional output modules
Ask an expert

    Our team of experts will asnwer your technical, product or application questions as soon as possible.

    Name*

    E-mail*

    Phone

    Company

    Country

    Message

    HOHNER AUTOMATION S.L. as the data controller will process your data for the purpose of replying to your query or request. You may access, rectify and erase your data, and also exercise other rights by consulting the additional detailed information on data
    protection in our Privacy Policy.

    I have read and accept the conditions contained in the privacy policy on processing of my data to manage my query or request.

    We would like you to give us your consent to:

    Send you commercial information about HOHNER AUTOMATION S.L.’s products, services and new features

    Fields with a * are required.

      Plaease enter your email to download product Datasheet.

      E-mail

      HOHNER AUTOMATION S.L. as the data controller will process your data for the purpose of replying to your query or request. You may access, rectify and erase your data, and also exercise other rights by consulting the additional detailed information on data
      protection in our Privacy Policy.

      I have read and accept the conditions contained in the privacy policy on processing of my data to manage my query or request.

      We would like you to give us your consent to:

      Send you commercial information about HOHNER AUTOMATION S.L.’s products, services and new features

      Fields with a * are required.

        Name*

        E-mail*

        Phone

        Company

        Country

        Message

        HOHNER AUTOMATION S.L. as the data controller will process your data for the purpose of replying to your query or request. You may access, rectify and erase your data, and also exercise other rights by consulting the additional detailed information on data
        protection in our Privacy Policy.

        I have read and accept the conditions contained in the privacy policy on processing of my data to manage my query or request.

        We would like you to give us your consent to:

        Send you commercial information about HOHNER AUTOMATION S.L.’s products, services and new features

        Fields with a * are required.

        TECHNICAL SPECIFICATIONS
        Digits 6
        Reading 999999 / -199999
        Decimal Point Configurable
        Led color Red (standard)
        Digit height 14 mm
        Signals accepted NPN, PNP, Namur, pick-up, TTL, inductive, mechanical, quadrature…
        Excitation voltage +5 Vdc, +9 Vdc, +15 Vdc, +18 Vdc (max. 70 mA)
        Máximum Vdc at input terminals ± 30 Vdc
        Quartz accuracy ± 0.01 %
        Thermal stability 20 ppm/ºC
        Display refresh 15 refresh / second
        Maximum frequencies Counter up to 250 KHz
        Ratemeter and periodmeter up to 500 KHz
        Mínimum frequencies Ratemeter and periodmeter down to 1 mHz (0.001 Hz)
        Power ‘H’ 85 a 265 Vac/dc (isolated 2500 Veff)
        Power ‘L’ 11 a 60 Vdc y 24/48 Vac (isolated 1500 Veff)
        Retransmission and control options Relays, analog output, serial communications…
        Consumption <1.5 W (meter only) <4.0 W (meter with options)
        Front protection IP65
        Connections Plug-in screw terminal
        Weight <150 grams
        Mounting Panel
        Front size 96 x 48 mm
        Panel cut-out 92 x 44 mm
        Deep 91 mm (including terminals)
        Operating temperature range 0 to +50ºC
        FUNCTIONS INCLUDED
        ‘Fast Access’ menu A single press on the front keypad gives access to alarm
        setpoint modification, preset, memories…
        ‘SLOW’ mode Special mode for low frequency ratemeter applications
        ‘FAST’ mode Special mode for high frequency counter applications
        Scaling factor Multiplier and divider from 1 to 999999
        Configurable reset Front and rear reset, and reset linked to alarm activation
        Preset Configurable
        Trigger level Configurable
        ‘Trigger sense’ function Help on setting the correct trigger level
        Sensor selection By menu
        Cycle counter Count of cycles defined by the ‘on alarm reset’ function
        Retention memory Recovers the counting value in case of power loss
        ‘On power-up’ function Protects remote systems by delaying the output and control
        signals at cold start-up
        Alarms With one or two setpoints, independent activation and
        deactivation delays, hysteresis, optional manual deactivation of
        the relay
        Inverted relay For security applications
        Display filters Recursive filters for unstable signals
        Brightness 5 levels of brightness intensity
        Password Blocks access to configuration menu