TECHNICAL SPECIFICATIONS | |
---|---|
Digits | 6 |
Reading | 999999 / -199999 |
Decimal Point | Configurable |
Led color | Red (standard) |
Digit height | 14 mm |
Signals accepted | NPN, PNP, Namur, pick-up, TTL, inductive, mechanical, quadrature… |
Excitation voltage | +5 Vdc, +9 Vdc, +15 Vdc, +18 Vdc (max. 70 mA) |
Máximum Vdc at input terminals | ± 30 Vdc |
Quartz accuracy | ± 0.01 % |
Thermal stability | 20 ppm/ºC |
Display refresh | 15 refresh / second |
Maximum frequencies | Counter up to 250 KHz Ratemeter and periodmeter up to 500 KHz |
Mínimum frequencies | Ratemeter and periodmeter down to 1 mHz (0.001 Hz) |
Power ‚H‘ | 85 a 265 Vac/dc (isolated 2500 Veff) |
Power ‚L‘ | 11 a 60 Vdc y 24/48 Vac (isolated 1500 Veff) |
Retransmission and control options | Relays, analog output, serial communications… |
Consumption | <1.5 W (meter only) <4.0 W (meter with options) |
Front protection | IP65 |
Connections | Plug-in screw terminal |
Weight | <150 grams |
Mounting | Panel |
Front size | 96 x 48 mm |
Panel cut-out | 92 x 44 mm |
Deep | 91 mm (including terminals) |
Operating temperature range | 0 to +50ºC |
FUNCTIONS INCLUDED | |
---|---|
‚Fast Access‘ menu | A single press on the front keypad gives access to alarm setpoint modification, preset, memories… |
‚SLOW‘ mode | Special mode for low frequency ratemeter applications |
‚FAST‘ mode | Special mode for high frequency counter applications |
Scaling factor | Multiplier and divider from 1 to 999999 |
Configurable reset | Front and rear reset, and reset linked to alarm activation |
Preset | Configurable |
Trigger level | Configurable |
‚Trigger sense‘ function | Help on setting the correct trigger level |
Sensor selection | By menu |
Cycle counter | Count of cycles defined by the ‘on alarm reset’ function |
Retention memory | Recovers the counting value in case of power loss |
‚On power-up‘ function | Protects remote systems by delaying the output and control signals at cold start-up |
Alarms | With one or two setpoints, independent activation and deactivation delays, hysteresis, optional manual deactivation of the relay |
Inverted relay | For security applications |
Display filters | Recursive filters for unstable signals |
Brightness | 5 levels of brightness intensity |
Password | Blocks access to configuration menu |