MECHANICAL SPECIFICATIONS | ||||
---|---|---|---|---|
Materials | Housing: Aluminium Flange: Aluminium Shaft: Stainless Steel |
|||
Bearings | Ballraces | |||
Bearings lifetime | 1×1010 rev. | |||
Housing fixing | Flexible flange 90.1129 (assembled) Flexible flange 90.1124 (assembled) |
|||
Permitted misalignment | ±0.4 mm axial, ±0.2 mm radial (90.1129) ±0.5 mm axial, ±0.1 mm radial (90.1124) |
|||
Maximum number of revolutions permitted mechanically | 6000 rpm | |||
Protection against dust and splashes according to DIN EN 60529 | IP66 | |||
Rotor inertia moment | 40 gcm2 (shaft 1) 30 gcm2 (shaft 2) |
|||
Starting torque at 20ºC (68ºF) | ≤ 0,02 Nm | |||
Maximum load permitted on axial shaft | 30 N | |||
Maximum load permitted on radial shaft | 40 N | |||
Weight aprox. | 0,25 Kg | |||
Operating temperature range | -20°C to +80°C | |||
Vibration according to DIN EN 60068-2-6 | 100 m/s2 (10Hz…2000Hz) (6ms) | |||
Shock according to DIN EN 60068-2-27 | 1000 m/s2 (6ms) | |||
Maximum pulses per turn | 1024 | |||
Radial connection | 2 meters cable (other cable lengths available on order) |
OUTPUT SIGNALS | ||||
---|---|---|---|---|
OUTPUT CIRCUIT | RS422 (TTL compatible) | Push-Pull Differential | ||
Power supply | 11…30 VDC | 5…30 VDC | ||
Output voltage | 5 VDC | 5…30 VDC | ||
Consumption | Tipical: 80 mA Max: 160 mA |
Tipical: 70 mA Max: 150 mA |
||
Max. load capability / channel | ±20 mA | ±30 mA | ||
Lenght of cable allowed | 1200 m | 100 m | ||
“Low” signal level | VOL < 0.5 VDC | VOL < 2.5 VDC | ||
“High” signal level | VOH > 2.5 VDC | VOH > VCC – 3 VDC | ||
Frequency | 300 kHz | 300 kHz | ||
Short circuit protection | Yes | Yes | ||
Protection polarity inversion | Yes | Yes | ||
Channel B leads (90° electric) channel A, view from the shaft, shaft rotating clockwise |